Sale!

ATC Diversified VCFP96M Multifunction/Power Meter

Original price was: $322.20.Current price is: $96.66.

SKU: ID2271496 Category: Tag:

Description

Automatic Timing & Controls Diversified, VCFP96M, Multifunction/Power Meter

Features:

  • 3Ø True RMS (Voltage/Current)
  • 3Ø Power (Active, Reactive, Apparent), Energy (Active, Reactive, Apparent)
  • Programmable CT/PT Primary/Secondary
  • CT Polarity Error Detection
  • Variable Pulse Width Selection
  • Single Phase Network with Phase Selection
  • Modbus RTU Communication (RS485)
  • Neutral Current Measurement
  • THD Up to 31st Level
  • Single Pulse Output/Demand Phase Sequence Detection

The VCFP96M is a complete single phase and three phase digital metering system suitable for low, medium and high voltage control panels, gensets, load banks, building management systems and power management systems. The VCFP96M can be used on single phase, three phase three wire as well as three phase four wire balanced or unbalanced systems. The six easy to access front control keys are used for scrolling up or down through the parameters being measured and displayed such as voltage, current, power factor, power (active, reactive, apparent), energy and frequency. Output specifications include pulse output and RS485 Modbus RTU communication protocol compatible with PC, PLC, RTU, data loggers and SCADA programs.

For more information, please see Data Sheet

Input
Electrical Connection
  • 3Ø – 3 wire
  • 3Ø – 4 wire
  • 2Ø – 3 wire
  • 1Ø – 2 wire
Input Voltage Range
  • 11 to 300V AC, (Phase to Neutral)
  • 19 to 519V AC (Phase to Phase)
Input Current Range Nominal 5A AC (Min-11mA, Max-6A)
Frequency 45 to 65Hz
Display Scrolling Automatic / Manual (Programmable)
Power Consumption 8VA Max
Display Reset Programmable (For energy)
Resolution
  • For energy: 0.01k, 0.1k, 1k, 0.01m, 0.1m, 1m (depending upon CT ratio x PT ratio)
  • For Power, Voltage, Current: Auto resolution
  • For Power factor: 0.001
Accuracy
  • Voltage (L-N / L-L): ±0.5% of F.S.
  • Power Factor ±0.01 Current ±0.5% F.S.
  • Frequency: ±0.1% For L-N Voltage >20V
  • For L-L Voltage >35V
  • Power (Active, Reactive, Apparent): 1%
  • Energy (Active, Reactive, Apparent): Class 1
Memory Retention 10 years (For energy)
Measuring Parameters
  • Voltage (L-L / L-N) (Individual / Average),
  • Current (I1, I2, I3) (Individual / Average),
  • Frequency, Power Factor (Individual /Total),
  • Active, Reactive & Apparent power
  • (Individual / Total),
  • Active, Reactive & Apparent Energy
  • (Total), Demand (Min / Max Active Power,
  • Min/Max Reactive Power,
  • Max Apparent Power), %THD up to 31st Level
  • Max Demand Current,
  • Neutral Current, Phase Sequence Detection
Output
Pulse Output
  • Voltage Range: External 24V DC max
  • Current Capacity: 100mA max
  • Pulse Width: 100 ms ± 5 ms
Communication Interface and Protocol RS485 and MODBUS RTU
Communication Address 1 to 255
Transmission Mode Half duplex
Transmission Distance 500 meter maximum
Transmission Speed 300, 600, 1200, 2400, 4800, 9600, 19200 (in bps)
Parity None, Odd, Even
Stop Bits 1 or 2
Response Time 100 ms (max and independent of baud rate)
Auxiliary Supply
Supply Voltage 100 to 240V AC, -15% +12%, 50/60 Hz, (±5%)
Settable Parameters
CT Primary 1/5A to 10kA (Programmable for any value)
CT Secondary 1/5A (Programmable)
PT Primary 100V to 500kV (Programmable for any value)
PT Secondary 100V to 500V (Programmable for any value)
Environmental Specifications
Temperature
  • Operating Temperature: -10 to 55°C
  • Storage Temperature: -20 to 75°C
Humidity (Non-Condensing) Up to 85% RH
Mechanical Specifications
Mounting Panel mount
Weight 318 gms

Reviews

There are no reviews yet.

Be the first to review “ATC Diversified VCFP96M Multifunction/Power Meter”

Your email address will not be published. Required fields are marked *

Add to cart